FMS Image Data Processing
ODP logging
contractor: LDEO-BRG
Hole: 1006A
Leg: 166
Location: Great Bahama Bank (tropical NW Atlantic)
Latitude: 24° 23.989' N
Longitude: 79°27.541' W
Logging date: March, 1996
Bottom felt: 669.4 mbrf
Total penetration: 717.3 mbsf
Total core recovered: 646.93 m (90.2 %)
FMS Pass: 289-421 mbsf
Magnetic declination: -4.755382°
Water depth: 668.3 mbrf
The basic principle of the FMS (Formation MicroScanner) is to map the conductivity of the borehole wall with a dense array of sensors. This provides a high resolution electrical image of the formation which can be displayed in either gray or color scale. The purpose of this report is to describe the images from Leg 166 and the different steps used to generate them from the raw FMS measurements.
The FMS tool records 4 perpendicular electrical images, using four pads, which are pressed against the borehole wall. Each pad has 16 buttons and the tool provides approximately 25% coverage of the borehole wall. The tool string also contains a triaxial accelerometer and three flux-gate magnetometers (in the GPIT, General Purpose Inclinometry Tool) whose results are used to accurately orient and position the images. Measurements of hole size, cable speed, and natural gamma ray intensity also contribute to the processing.
The FMS images in Hole 1006A are of
moderate quality, with the exception of the interval from the top of the logged
interval down to 380 mbsf, where the hole size is often enlarged and irregular
(two pads lost contact with the borehole wall from 155 to 275 mbsf. Conductive
levels (dark) correlate well with wide calipers opening and correspond to hole
enlargements. Furthermore, numerous thin conductive laminations are detected on
the FMS images (for instance in the 415-422 mbsf interval), which are related
to the overprint left by the rotation of the drill-bit during drilling on the
borehole wall. As a consequence, any lithologic or structural interpretation of
the conductive features must be made with caution.
Higher quality FMS images were recorded in the lower section, from 380 to 715 mbsf. Regular resistive bands within a more conductive matrix characterize this interval. In the 380-420 mbsf interval, 20 to 30 cm thick resistive bands are irregularly spaced, while in the 515-715 mbsf interval, occurrence is more frequent and regular. The matrix conductivity decreases in the 420-515 mbsf interval, where the moderate hole conditions partially mask the resistive cyclical layering, and below 565 mbsf. At 404 mbsf, a thin resistive planar event is detected and shows a steep dip to the SW.
Image
Processing
Processing is required to convert the electrical current in the formation, emitted by the FMS button electrodes, into a gray or color-scale image representative of the conductivity changes. This is achieved through two main processing phases: data restoration and image display.
1) Data Restoration
Speed
Correction. The data from the z-axis accelerometer is used to correct the
vertical position of the data for variations in the speed of the tool (GPIT
speed correction), including stick and slip. In addition, image-based speed
correction is also applied to the data: the principle behind this is that if
the GPIT speed correction is successful, the readings from the two rows of
buttons on the pads will line up, and if not, they will be offset from each
other (a zigzag effect on the image).
Equalization: Equalization is the process whereby the average response
of all the buttons of the tool are rendered approximately the same over large
intervals, to correct for various tool and borehole effects which affect
individual buttons differently. These effects include differences in the gain
and offset of the pre-amplification circuits associated with each button, and
differences in contact with the borehole wall between buttons on a pad, and
between pads.
Button Correction. If the measurements from a button are unreasonably
different from its neighbors (e.g. dead buttons) over a particular interval,
they are declared faulty, and the defective trace is replaced by traces from
adjacent good buttons.
EMEX voltage correction. The button response (current) is controlled by the EMEX voltage, which is applied between the button electrode and the return electrode. The EMEX voltage is regulated to keep the current response within the operating range. The button response is divided by the EMEX voltage so that the response corresponds more closely to the conductivity of the formation.
Depth-shifting: Each of the logging runs are depth-matched to a common scale by means of lining up distinctive features of the natural gamma log from each of the tool strings. If the reference logging run is not the FMS tool string, the specified depth shifts are applied to the FMS images. The position of data located between picks is computed by linear interpolation.
2) Image Display:
In "static normalization", a histogram equalization technique is used to obtain the maximum quality image. In this technique, the resistivity range of the entire interval of good data is computed and partitioned into 256 color levels. This type of normalization is best suited for large-scale resistivity variations.
The image can be enhanced when it is desirable to highlight features in sections of the well where resistivity events are relatively subdued when compared with the overall resistivity range in the section. This enhancement is called "dynamic normalization". By rescaling the color intensity over a smaller interval, the contrast between adjacent resistivity levels is enhanced. It is important to note that with dynamic normalization, resistivities in two distant sections of the hole cannot be directly compared with each other. A 2-m normalization interval is used.
For further information or questions about the processing,
please contact:
Cristina Broglia
Phone: 845-365-8343
Fax: 845-365-3182
E-mail: Cristina Broglia