Tools & labs > Logging
tools
Downhole logging tools
7-46 P
Seven conductor armored cable, designed and specially manufactured for use in well logging. The armor wires are high tensile, galvanized improved plow steel, pre-formed and pre-stressed. The armor is coated with an anticorrosion compound.
20 AWG copper
6 / 0.014"
6 / 0.36 mm
EPC insulation
0.102"
2.59 mm
20 AWG copper
7 / 0.013"
7 / 0.32 mm
EPC insulation
0.098"
2.49 mm
Filler rods, filler compound
& tape binder --
Compressed Diameter
0.288"
7.32 mm
Inner armor
24 / 0.039"
24 / 0.99 mm
Outer armor
24 / 0.049"
24 / 1.24 mm
Nominal Diameter
0.464"
11.79 mm
Nominal Properties
ELECTRICAL
DC Resistance @ 68° F or 20° C
Conductor:
10.9 ohm/kFt
36 ohm/km
Armor:
1.2 ohm/kFt
4 ohm/km
Insulation Resistance
at 500 VDC
15000 M ohm/kFt
5000 M ohm/km
Capacitance
at 1 KHz
40 pf/Ft
131 pf/km
Voltage Rating
880 Vrms
880 Vrms
MECHANICAL
Calculated Weight
In air
335 Lbs/kFt
498 kg/km
In fresh water
264 Lbs/kFt
393 kg/km
Temperature Rating
Min.
- 40° F
- 40° C
Max.
300° F
150° C
Break Strength
Ends fixed
16700 Lbf
74 kN
Ends free
11600 Lbf
52 kN
Maximum end to end variation
0.010 Inch
0.254 mm
Back to Wireline